ONSMFS17 / MFS20 / MFS24 / MFS27A / MFS27 / MFS31AMFS31 / MFS351. Sand füllen Abdeckung.2. Platzam tanköffnen.3. Fügen Sie Wasserzur DeckungSeitenteile undFügen Sie Sand.MODELL: MFS17(88012626), MFS20(88012627), MFS24(88012628), MFS27A(88012629), MFS27(88012630), MFS31A(88012631), MFS31(88012632), MFS35(88012633)EMFI10042302WassertechnikWassertechnikEFC ABDSchlüssel Nr. Teil Nummer Produktbeschreibung QTY1 89010701 Luft Ventil 12 06021002 aus Kunststoff Manometer mit o-Ring (40 Psi) 13 01111048 Anschluss für Manometer/Stopper 14 01201022 Deckel (Transparent) 15 01271021 Klammerverschluss (links) 16 01271022 Klammerverschluss (rechts) 17 03021035 M6 Mutter 18 01111101 sternförmigen Mutter 19 03011166 M6 × 110mm Schrauben 110 03018124 Pin 111 02010007 o-Ring 101331036 MFS17 Filterbecken 101331037 MFS20 Filterbecken 101331038 MFS24 Filterbecken 101331049 MFS27A Filterbecken 101331039 MFS27 Filterbecken 101331050 MFS31A Filterbecken 101331040 MFS31 Filterbecken 101331041 MFS35 Filterbecken 188280805 1.5" Side Mount Ventil für MFS17 MFS20 MFS24 MFS27A MFS31A Filtern MAX 188280806 2.0" Side Mount Ventil für MFS27 MFS31 MFS35 Filtern MAX 101015002 1.5" Connecting Nuss für MFS17 MFS20 MFS24 MFS27A MFS31A Filter MAX 201015003 2.0" Connecting Nuss für MFS27 MFS31 MFS35 Filter MAX 202011003 o-Ring für Ventilanschluss für MFS17 MFS20 MFS24 MFS27A MFS31A Filter MAX 202020016 o-Ring für Ventilanschluss für MFS27 MFS31 MFS35 Filter MAX 202010009 Spacer for Connecting panel for MFS17 MFS20 MFS24 MFS27A MFS31A Filter MAX 202010010 Spacer for Connecting panel for MFS27 MFS31 MFS35 Filter MAX 301172033 1.5" Connecting panel for MFS17 MFS20 MFS24 101172002 1.5" Connecting panel for MFS27A MFS31A 101170014 2.0" Connecting panel for MFS27 MFS31 MFS35 189012611 Air Vent Pipe for MFS17 189012612 Air Vent Pipe for MFS20 189012613 Air Vent Pipe for MFS24 189012614 Air Vent Pipe for MFS27A MFS27 189012615 Air Vent Pipe for MFS31A MFS31 189012616 Air Vent Pipe for MFS35 189012601 MFS17 Top part of the inner tank system 189012602 MFS20 Top part of the inner tank system 189012603 MFS24 Top part of the inner tank system 189012604 MFS27A Top part of the inner tank system 189012617 MFS27 Top part of the inner tank system 189012605 MFS31A Top part of the inner tank system 189012618 MFS31 Top part of the inner tank system 189012619 MFS35 Top part of the inner tank system 101111046 1.5"Tank System Support for MFS17 MFS20 MFS24 101111043 1.5"Tank System Support for MFS27A MFS31A 101110018 2.0"Tank System Support for MFS27 MFS31 MFS35 189012606 MFS17 Bottom part of the inner tank system 189012607 MFS20 Bottom part of the inner tank system 189012608 MFS24 Bottom part of the inner tank system 189012609 MFS27A Bottom part of the inner tank system 189012620 MFS27 Bottom part of the inner tank system 189012610 MFS31A Bottom part of the inner tank system 189012621 MFS31 unteren Teil der inneren Tankanlage 189012622 MFS35 unteren Teil der inneren Tankanlage 101172007 Seitenteile (115mm) für MFS17 801172008 Seitenteile (126mm) für MFS20 MFS24 MFS27A MFS31A 801172010 Seitenteile (185mm) für MFS27 MFS31 MFS35 401172007 Seitenteile (115mm) für MFS27 MFS31 MFS35 423 89012516 Abzweigstücke Halterung für MFS27 MFS31 MFS35 424 89011601 Abfluss-Set 101111059 filter Basis für MFS17 MFS20 101111062 filter Basis für MFS24 MFS27A MFS27 101331003 filter Basis für MFS31A MFS31 MFS35 1252221201918161714151312STAUBSAUGEN DES POOLSLeichten Böden: Legen Sie das Regelventil auf Filterposition.Schweren Böden: Stellen Sie das Regelventil auf Abfall Position.WINTERRISINGRückspülung der Filter für mindestens dreißig Minuten vorSchließen Sie den Pool für Umwälzpumpen. Dies wird sauberdie Filter gründlich Bett.1 / drain Filterbecken durch Entfernen der Abfluss Kappe an derBasis des Filterbeckens. Lassen Sie die Kappe ausgeschaltet, während derWinter.2 / Satz Ventilgriff zwischen die Spülung undFILTERN. Dies wird den Handgriff und helfen Sie mit dieEntwässerung Prozess indem Luft in treten dieTank.3 / das Manometer aus dem Regelventil abschraubenund bewahren Sie das Messgerät indoor.4 / drain und ADAC Pumpe nach PumpeAnweisungen.5 / Reparaturen sollten in der Nebensaison erfolgen beider beste Service ist nicht verlassen, bis siedie nächste Saison.TROUBLE-SHOOTINGSAND ZURÜCK ZUM POOLSand zu klein; Durchfluss zu hoch; Sandbett verkalkt;Broken Laterals; Loose centre-pipe; Too much sand;Control Valve not engaged; Air accumulation in filter.SAND OUT OF BACKWASH HOSEFlow too high; Too much sand in tank.INADEQUATE FILTERINGDirty make-up water; improper sand; Sand is too low;Algae in filter; Excessive dirt in pool; Calcified sandbed; Heavy swimmer load; Flow rate too high or toolow; Backwashing cycle too short; Backwash line toosmall.SHORT FILTER CYCLEDirty filter; Improper sand; Sand is low; Algae in filter;Excessive dirt in pool; Calcified sand bed; heavyswimmer load; Flow rate too high or too low;Backwashing cycle too short; Channels low;Backwash adapter in wrong location; Channels insand.FILTER LEAKSTank cracked; Drain plug not tight; Valve/Tank O'ringdamaged.CONTROL VALVE LEAKSHandle not properly engaged; Valve/Tank O'ringdamaged; Valve cover O'ring damaged. Pressuregauge O'ring damaged.ABNORMAL LOSS OF POOL WATERLeak inside Control Valve; Leakage from pool orpiping.HIGH PRESSURE FILTERDirty filter; Calcified sand bed; Return lines too small.LOW PRESSURE IN FILTERControl Valve incorrectly set; Pump running too slow(plugged or clogged); Air leakage into pump suction.NOTE: If the recommendation in this manual do notsolve your particular problem(s), please contactyour local dealer for service.2-4 3-43/ Pour the recommended amount of sand into thetank, making sure that the centre-pipe remainscentred and vertical.4/ Level the surface of the sand upon completion.5/ Remove the Sand Fill Cover.6/ Carefully remove all sand particles from the valvemounting surface.7/ Place the O-ring into the groove on the tank.8/ Lower the Multiport Control Valve carefully intoposition so that its underside engages with thecentre-pipe. Rotate the valve until the inlet isapproximately in line with the pump.9/ Place the clamp set around the tank. Secure usingthe screw provided.10/ Firmly tap with a rubber mallet outside of theclamps as you tighten the screw.11/ Install the Multiport Control Valve to the filter. Makesure the unions of inlet and outlet are tighten.START-UP PROCEDURE1/ Be sure the correct amount of filter sand media is inthe tank and all connections have been made andare secure.2/ Turn the Control Valve handle to the “Backwash”position. Press the handle downward beforeturning.3/ Start the pump according to pump instructionmanual (be sure all suction and return lines areopen).4/ Once water flow is steady out the waste line, run thepump for at least 2 minutes. The initial backwashingof the filter is recommended to remove anyimpurities or fine sand particles in the sand media.5/ Turn the pump off and set the control valve to RINSEposition. Start pump and operate until water in sightglass is clear about ½ to 1 minute. Turn pump off,set valve to FILTER position and restart pump. Yourfilter is now operating in the normal filter mode,filtering particles and dirt from the pool water.6/ Take note of the initial pressure gauge reading for
future reference. Variation may occur from pool to
pool.
7/ Adjust pool suction and return valves to achieve
desired flow. Check system and filter for water
leaks and tighten connections, bolts, nuts as
required.
NOTE: During the initial clean-up of the pool water,
it may be necessary to backwash frequently due
to the unusually heavy initial dirt load in the
water.
IMPORTANT: To prevent unnecessary strain on piping
system and control valve, always turn off the pump
before changing the operation of the control valve.
To prevent damage to the pump and filter and for
proper operation of the system, clean pump strainer
(basket) and skimmer basket(s) regularly.
MULTIPORT CONTROL VALVE FUNCTIONS:-
FILTER gives downward flow through the filter bed.
This position can also be used for vacuuming.
BACKWASH gives upward flow through the filter bed
that removes the dirt from the sand and carries it to
the waste.
WASTE is for pumping water from the pool. It allows
the flow from the pump to bypass the filter and go
directly to the waste. You can also use this position
to vacuum heavy concentration of debris.
RECIRCULATE bypasses the filter to circulate water
through the pool system.
RINSE gives a downward flow that settles the filter bed
after backwashing and carries any remaining loose
dirt to the waste.
CLOSED prevents only backflow of water from pool
during pump maintenance.
To WINTERISE, set the control valve handle in the
middle between RINSE and FILTER. This will allow
air to leave or enter the tank to help priming and
Übersetzt wird, bitte warten..